Characteristics and working principle of 2507 duplex steel gate valve (diagram)

Working principle of 2507 duplex steel gate valve (diagram)
The opening and closing component of the 2507 duplex steel gate valve is the gate, and the movement direction of the gate is perpendicular to the fluid direction. The gate valve can only be fully opened and fully closed, and cannot be adjusted or throttled. When the gate valve is closed, the sealing surface can be sealed solely by the pressure of the medium, that is, the sealing surface of the gate is pressed against the valve seat on the other side by the pressure of the medium to ensure the sealing of the sealing surface. Most gate valves use forced sealing, which means that when the valve is closed, it relies on external force to forcefully press the gate plate against the valve seat to ensure the sealing performance of the sealing surface.
Characteristics of 2507 duplex steel gate valve
1. Compact structure, reasonable design, good valve rigidity, smooth channel, and small flow coefficient;

2. The sealing surface is made of stainless steel or hard alloy, with a long service life;

3. Using flexible graphite packing, reliable sealing, and easy and flexible operation;

4. Electric devices can be selected from ordinary switch type or intelligent control switch type;

5. The structural forms are elastic wedge single gate and rigid wedge single gate double gate.

Installation precautions and key points for 2507 duplex steel gate valve:
1. Handwheels, handles, and transmission mechanisms are not allowed to be used for lifting and collisions are strictly prohibited.

2. It should be installed vertically (i.e. the valve stem is in a vertical position and the handwheel is at the top).

3. Before opening a gate valve with a bypass valve, the bypass valve should be opened first (to balance the pressure difference between the inlet and outlet and reduce the opening force).

4. Install the gate valve with transmission mechanism according to the instructions in the product manual.

5. If the valve is frequently opened and closed, lubricate it at least once a month.

6. The installation position, height, and import/export direction must meet the design requirements, and the connection should be firm and tight.

7. All types of manual valves installed on insulated pipelines must not have handles facing downwards.

8. Install the gate valve with transmission mechanism according to the instructions in the product manual.

Recommend Article

Valve supply requirements

General requirements 1) The valve must be manufactured in accordance with its corresponding technical standards, design drawings, technical documents and

Read More »

Product recommendation

Ball Valve , Gate Valve , Check Valve , Globe Valve , Butterfly Valve , Plug Valve , DIN Valve , Gost Valve , Bellow Seal Valve , Stainless Steel Pipe , Stainless Steel Flange , Stainless Steel Fitting .

Contact Us

Wuhan Furun Yang Valve Co., Ltd.

  • ylei95@gmail.com
  • Copyright 2020 Valves